home
products
stepper
motors gear
box, encoder and brake for STÖGRA stepper motors |
|
|
|
|
Encoder for STÖGRA stepper motors |
|
|
|
|
|
|
In non disturbed operation the stepping motor runs synchronously to the pulses coming from
the control. That means the motor rotation (= rotation of the rotor) is synchronously to the pulse
frequency (= rotating stator field in the motor).
In case of a load at the motor (e.g. via a static load at the motor shaft or because of accelerating
the motor – dynamical load) the running of the motor will differ from the pulse frequency within
a short time and within a certain max range.
This results in a change of the load angle (= difference between the real position of the rotor and
its position command value).
By using an encoder, mounted at the motor, the load angle can be monitored, and a mechanical overload
at the motor can be detected.
|
|
|
|
|
|
|
encoder E50 |
|
|
|
encoder H200/H500 |
|
|
|
|
Download |
|
|
|
encoder
types E50, H200 and H500 – data sheet (57 KByte) |
|
|
|
stepper
motors catalogue 2016 – Catalogue (850 KByte) |
|
|
|
|
|
|
stepper motors I
position controls I
power amplifiers I equipment
I home I info@stoegra.de |
|
|